20% OFF shipping at www.midwoodautocraft.com on orders over $79 + up to 10% OFF products
www.midwoodautocraft.com
home > Woodward 9905-068 Load Sharing Governor for Generators > Woodward 9905-068 Load Sharing Governor for Generators
download picture
Woodward 9905-068 Load Sharing Governor for GeneratorsProduct Overview The Woodward 9905 068 serves as a primary electronic governor for engine and turbine systems, specifically within the legendary 2301A product family. This 100% Brand New and Original module manages prime mover speed and facilitates proportional load sharing between multiple parallel running generators. It detects speed via magnetic pickups (MPU) and drives proportional actuators to maintain a steady state, even during severe load
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Overview

The Woodward 9905-068 serves as a primary electronic governor for engine and turbine systems, specifically within the legendary 2301A product family. This 100% Brand New and Original module manages prime mover speed and facilitates proportional load sharing between multiple parallel-running generators. It detects speed via magnetic pickups (MPU) and drives proportional actuators to maintain a steady state, even during severe load transients. Engineered for rugged industrial environments, the 9905-068 provides the essential logic required for stable power generation, marine propulsion, and oil & gas compressor drives.

Technical Specifications

Parameter Details
Model Number 9905-068
Control Series 2301A High-Voltage/Low-Voltage variant
Input Power 18–32 VDC (Standard Industrial Battery)
Speed Sensor Range 1,000 Hz to 20,000 Hz
Actuator Output 20–200 mA (Proportional)
Operating Modes Isochronous Speed, Droop Speed, Load Sharing
Operating Temp -40 to +70 deg C
Dimensions 20.3 cm x 12.7 cm x 2.5 cm
Weight 0.2 kg (Module weight)
Certifications CE, UL, CSA, Marine Approvals

Engineering Advantages

  • Deterministic Analog Response: The 2301A architecture utilizes analog circuitry to provide instantaneous response to load changes. This prevents the computational lag sometimes found in older digital units, ensuring your engine reacts immediately to prevent overspeed or frequency dips.

  • Proportional Load Distribution: This module coordinates with other 2301A units through a dedicated load-sharing lines interface. It forces multiple generators to share the total kilowatt load proportionally to their individual capacities, preventing "load fighting" and ensuring grid stability.

  • Streamlined Field Commissioning: Front-panel potentiometers allow technicians to perform precise calibrations—including Gain, Reset, and Rated Speed—without specialized software or laptops. This manual interface simplifies setup in remote areas or high-security facilities where external data devices are restricted.

  • Superior Environmental Hardening: Woodward builds the 9905-068 to withstand the extreme thermal cycles and vibrations found in engine-mounted control cabinets. The wide -40 to +70 deg C operating range ensures reliable startup in arctic conditions and continuous operation in tropical or desert climates.

FAQs

  • Can the 9905-068 replace a digital 2301D controller?

    • While the 9905-068 performs similar functions, it is an analog module. Replacing a digital unit requires a review of the wiring and configuration logic. However, for systems that prioritize simplicity and analog speed of response, the 2301A remains the industry standard.

  • How do I troubleshoot a "Loss of Speed Signal" fault?

    • First, measure the AC voltage across the MPU inputs; it must exceed 1.5 Vrms during cranking. Inspect the MPU air gap and ensure the shielded cable remains grounded at only one end to prevent electrical noise interference.

  • Does this module support load sharing with third-party governors?

    • The 9905-068 uses Woodward’s standard load-sharing lines. To interface with non-Woodward controls, you may require a load-sharing gateway or interface module. It works seamlessly with other Woodward 2301A, 2301D, and 8272 series units.

  • What is the recommended maintenance for the potentiometers?

    • Once you reach the optimal setpoints, we recommend applying a small drop of calibration lacquer to the potentiometer screws. This prevents "creep" caused by the high-frequency vibration common in diesel engine applications.

Woodward 9905-068 Load Sharing Governor for Generators

Item no : 10957681489
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 10 - Aug 15

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches