Shopping security
Product Line |
ORIX® |
Fan Type |
Axial Fan |
Frame Size |
4.69 in |
Thickness |
1 in. |
Power Supply |
24 VDC |
Current |
0.34 A |
Function |
Low Speed Alarm - Electronic |
Connection Type |
Lead Wire |
Type |
Standard Speed |
Speed (r/min) |
3000 |
Max. Air Flow |
95.3 CFM |
Max. Static Pressure |
0.281 inH2O |
Noise Level |
46 dB (A) |
RoHS Compliant |
These products do not contain substances that exceed the regulation values in the RoHS Directive. |
Safety Standards |
IECULCSAENCE |
CE Marking |
EMC Directives |
Insulation Resistance |
10 MΩ or more when 250 VDC is applied between the windings and the frame under normal ambient temperature and humidity. |
Dielectric Strength |
Sufficient to withstand 500V at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity. |
Temperature Rise |
18ºF (10ºC) or less measured by the thermometer method after the temperature of the case has stabilized after continuous operation under normal ambient temperature and humidity. |
Insulation Class |
Class E (248ºF [120ºC]), Recognized as Class A (221ºF [105ºC]) by UL and CSA standards. |
Overheat Protection |
Built-in Overheat Protection Circuit |
Ambient Temperature Range |
14ºF ~ 140ºF (-10ºC ~ 60ºC) |
Ambient Humidity |
85% or less (noncondensing) |
Alarm Type |
Electronic |
Alarm Activation Speed |
2100 ± 400 r/min |
Output Mode |
Open-collector output |
Output Condition |
Normal operation: L level (Internal transistor ON) Alarm output: H level (Internal transistor OFF) |
Maximum Rating |
Maximum applied voltage: 30 VDC max. Maximum current: 15 mA max. |
Delay Function |
Built-in starting delay time: 10 sec. max. (The alarm function starts monitoring within 10 seconds after the power is turned on.) |