20% OFF shipping at www.midwoodautocraft.com on orders over $79 + up to 10% OFF products
www.midwoodautocraft.com
home > YOKOGAWA Probe Style Tunable Diode Laser Spectrometer TDLS8100/TDLS8200 > YOKOGAWA Probe Style Tunable Diode Laser Spectrometer TDLS8100/TDLS8200
download picture
YOKOGAWA Probe Style Tunable Diode Laser Spectrometer TDLS8100/TDLS8200Overview The TDLS Probe brings all the industry leading combustion features into a single flange explosion proof device for measuring oxygen, CO, and methane. Whether it's being used for oxygen trim control, CO monitoring, high combustible fuel runback control, or even a SIL2 rated startup permissive for methane, the TDLS Probe Type is capable of providing measurements for all of these functions in a single device. Benefits Reduced Installation and
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Overview

The TDLS Probe brings all the industry-leading combustion features into a single-flange explosion-proof device for measuring oxygen, CO, and methane. Whether it's being used for oxygen trim control, CO monitoring, high combustible fuel runback control, or even a SIL2-rated startup permissive for methane, the TDLS Probe Type is capable of providing measurements for all of these functions in a single device.

Benefits

Reduced Installation and Maintenance Costs

  • Single-flange design allows for installations where cross-duct TDLS technology was not feasible due to obstructions or accessibility issues
  • Capability to make O2 + CO/CH4 Measurements with a single device up to 850°C
  • Onboard diagnostics with 50 days of data and spectral storage ensure that minor issues can be identified before they become more serious problems
  • Explosionproof/flameproof for installation in CID1/Z1 or CID2/Z2 areas
  • HART and Modbus TCP come standard to maximize remote diagnostics and configuration capabilities with a single cable run

Reliability

  • Reference Cell

Internal reference cell in the laser/detector module ensures peak locking

  • Auto-gain

Auto-gain enables a wide signal range during dynamic process events

  • Validation

Initiated manually, remotely, or automatically on a daily, weekly or monthly basis defined by the user

  • SIL2 Certified

IEC61508 SIL designed & approved, SIL2 capability for single analyzer use, SIL3 capability for dual analyzer use.

Features

Single flange design reduces total installed cost

  • Ideal for smaller fired assets or installation points where clear aperture cannot be achieved
  • Reduced overall installed cost for additional nozzles, alignment services, or platform installation

Replacing of existing extractive gas sampling analyzer

  • Reduced overall maintenance demand with no consumables and negligible drift (eliminates calibration)
  • In-situ measurement removes sample lag time

Specifications

Measurement object O2, CO, CO/CH4, O2+CO/CH4, NH3, HCl
Measurement system Tunable diode laser spectroscopy
Measured components and range Measured component Min. range Max. range
O2 0-1% 0-25%
CO(ppm) 0-200 ppm 0-10,000 ppm
CO+CH4 CO 0-200 ppm 0-10,000 ppm
CH4 0-5 %
NH3 0-30 ppm 0-50,000 ppm
HCl 0-50 ppm 0-5,000 ppm
Probe Length 0.7m, 1.0m, 1.5m, and 2.0m
Output signal 2 or 5 points (TDLS8100/TDLS8200), 4 to 20 mA DC
(Analog Output) Output types; Gas 1 concentration, Gas 2 concentration, Gas 3 concentration, Transmission, Process gas temperature, Process gas pressure
Output range; 3.0 to 21.6 mA DC
Digital communication HART, Ethernet
Contact outputs 2 points, contact rating 24 V DC, 1 A
(Digital Output) DO;
Function: Activate during Warning / Calibration / Validation / Warm up / Maintenance conditions
Fault;
Function: Activate during normal condition, not activate during fault condition or when the system power is off
Valve control output 2 points
Function; Activate calibration or validation solenoid valves for zero, span or validation gas
Output signal; 24 V DC, 500 mA Max. per terminal
Alarm Warning;
Gas concentration low/high, Transmission low, Process pressure low/high, Process temperature low/high, Validation required, Validation failure, Zero/Span calibration error, Non process alarm, External alarm
Fault;
Laser module temperature low/high, Laser temperature low/high, Detector signal high, Peak center out of range, Reference peak height low, Absorption too high, Transmission lost, Reference transmission low, Reference peak height high, Laser unit failure, Laser module error, File access error, E2PROM access error.
Contact inputs 2 points
(Digital input) Function;
External alarm/Calibration start/Validation start/Stream switch
Contact specification;
Zero voltage contact input
Input signal; Open signal;
100 kΩ or more, Close signal; 200 Ω or less
Input signal 2 points, 4 to 24 mA DC
(Analog input) Input types; Process gas temperature, Process gas pressure
Self-diagnostics Laser Unit temperature, Sensor Control Unit temperature, Laser temperature, Detector signal level, Memory read/write function, Peak locking condition
Calibration Calibration method; Zero/Span calibration
Calibration mode; Manual, Auto, Local initiate (HMI)
Validation Validation method; Up to 2 points
Validation mode; Manual, Auto, Local initiate (HMI)
Power supply 24 V DC ±10%
Warm-up time 5 min.
Protection degree IP66, NEMA Type 4X
Hazardous area classifications Division 1, Zone 1; Explosion-proof/ Flame-proof type; FM, cFM, ATEX, IECEx (Pending)
Process gas condition Process gas temperature: Max 850°C
Process gas pressure: 90 to 500 kPa abs.
Process gas flow velocity: 1 to 30 m/sec
Installation condition Ambient operating temperature: -20 to +55°C
Storage temperature: -30 to +70°C
Humidity: 0 to 95%RH at 40°C (non-condensing)
Additional Specifications Cable entries; 1/2 NPT or M20x1.5mm, one hole and 3/4 NPT or M25x1.5mm, three holes
Purge gas connections; 1/4 NPT or Rc 1/4
Recommended purge gasses;
  O2 analyzer: N2 (99.99% or greater, application dependent)
  CO, CO/CH4, NH3, and HCl analyzers: N2 (99.99% or greater, application dependent) or instrument air

YOKOGAWA Probe Style Tunable Diode Laser Spectrometer TDLS8100/TDLS8200

Item no : 34794778065
sold recently : Login >>
US$ 500.00
Pay in 4 interest-free payments of $125.00 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 14 - Jul 19

Enjoy 20% off shipping

US$ 500.00

1-11

US$ 450.00

12-35

US$ 350.00

36-59

US$ 300.00

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches