The Yokogawa NFTR85-10, also cataloged as the Yokogawa NFTR85-10 Terminal Block Unit, operates as a dedicated hardware component for field wiring interface execution within CENTUM VP / CS 3000 FIO platforms. It routes multi-channel physical input and output signals directly between electronic I/O modules and external field equipment via localized terminal architecture.
| Parameter | Specification |
|---|---|
| Model | NFTR85-10 |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | 0.2 kg |
| Dimensions | 114 x 32.6 x 60.5 mm |
| Operating Temp | -20 to +55 deg C |
| Power Consumption | Passive component (No external power required) |
| Subsystem Compatibility | CENTUM VP / CS 3000 FIO |
| Connector Type | MIL connector |
| Channel Capacity | 32 signal points per block |
| Maximum Voltage | 250 VAC / VDC |
| Current Rating | 5 A maximum continuous per common bus |
| Dielectric Strength | 1500 VAC for 1 minute |
| Insulation Resistance | 100 Mohm or greater at 500 VDC |
| Protection Mechanism | Built-in surge absorber |
As a standard component within Yokogawa process automation topologies, this interface unit supports the physical propagation of 4-20 mA HART loop protocol parameters without data attenuation. The internal copper traces maintain localized channel-to-channel isolation baselines to counter common-mode noise issues in analog data streams. The integrated surge absorber architecture protects the 32 discrete connection lines from high-voltage transient spikes generated by external inductive loads like solenoids or relays, preventing electrical damage from reaching backplane I/O cards.
Q: Does the NFTR85-10 require a distinct external power supply connection?
A: No. The unit functions as a completely passive mechanical and electrical interface board. It handles signal pass-through and localized surge absorption without drawing power from an external source or the subsystem backplane.
Q: What is the mechanical limitation regarding hot-swapping cables via the MIL connector?
A: The MIL connector interface permits rapid connection and disconnection for maintenance. However, individual field wiring circuits must be de-energized prior to disconnecting the multi-core cable to prevent inductive arcing across the pins.