20% OFF shipping at www.midwoodautocraft.com on orders over $79 + up to 10% OFF products
www.midwoodautocraft.com
home > 5466-353 Woodward Analog Transceiver Board | New & Original Stock > 5466-353 Woodward Analog Transceiver Board | New & Original Stock
download picture
5466-353 Woodward Analog Transceiver Board | New & Original StockWoodward 5466 353 MicroNet Series Configured for high speed analog signal translation in MicroNet and NetCon platforms, the Woodward 5466 353 (5466 353 Analog Transceiver Board) provides direct physical electrical execution. Hardware Specifications Parameter Specification Model 5466 353 Brand Woodward Origin United States Weight Not specified Dimensions Not specified (standard MicroNet chassis slot form factor) Operating Temp 20 to +70 deg C Power
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Woodward 5466-353 MicroNet Series

Configured for high-speed analog signal translation in MicroNet and NetCon platforms, the Woodward 5466-353 (5466-353 Analog Transceiver Board) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model 5466-353
Brand Woodward
Origin United States
Weight Not specified
Dimensions Not specified (standard MicroNet chassis slot form factor)
Operating Temp -20 to +70 deg C
Power Consumption 24 VDC Nominal (Accepts 18 to 32 VDC)
Module Type High-Density Transceiver / Analog I/O
Input Configuration 8 Differential Channels
Input Signal Ranges 4-20 mA, 0-5 VDC, or +-5 VDC (Software Selectable)
Output Configuration 4 Proportional Channels (4-20 mA)
Resolution Configurable 12-bit to 16-bit A/D and D/A
Calibration Accuracy +-0.1% of Full Scale over operating temperature range
Galvanic Isolation 500 VRMS (Channel-to-System and Channel-to-Channel)
Humidity Range 5% to 95% non-condensing

Industrial Drives & Governors Properties

The Woodward 5466-353 features optimized thermal heat sink dissipation profiles to stabilize the internal operational amplifiers during high-density channel utilization. The component executes highly responsive actuator loop feedback response metrics, which mitigates loop dead time within the turbine governing logic. The 8 differential input and 4 proportional output stages interface directly with hydraulic actuator drivers, utilizing the software-configurable 12-bit to 16-bit conversion matrix to match the precise dynamic tracking constraints required for deterministic real-time valve positioning.

Frequently Asked Questions

Q: How is the input channel signal range configured on the 5466-353?

A: The selection between 4-20 mA, 0-5 VDC, and +-5 VDC signal envelopes is fully software-defined through the application software. No manual physical jumper modification on the transceiver circuit board is required.

Q: What are the galvanic isolation boundaries for this analog transceiver board?

A: The board features 500 VRMS galvanic isolation. This protective threshold is enforced both between the field channels and the system logic backplane, as well as between individual input/output channels to prevent cross-channel electrical noise propagation.

Q: Can this module operate within volatile temperature environments?

A: The hardware is rated for an industrial operating temperature range from -20 deg C up to +70 deg C, allowing installation inside standard unconditioned turbine control enclosures provided condensation is managed.

Field Installation Guidelines

  • Chassis Insertion: Guide the transceiver board along the chassis card guides of the MicroNet or NetCon enclosure. Firmly seat the rear plug-in connectors into the backplane, then tighten the top and bottom thumbscrews to secure the physical ground contact.
  • Shielding Protocol: Terminate all analog field wiring using twisted-shielded pairs. Connect the cable shields exclusively to the designated chassis ground bus bar at the entry point of the control cabinet; do not ground both ends of the shield to eliminate ground loops.
  • Signal Separation: Maintain physical separation between the low-voltage 4-20 mA / VDC transceiver signal lines and high-voltage AC power or discrete inductive switching lines within the wire ducting.
  • Field Wiring Terminations: Ensure all terminal block connections are torqued to manufacturer specifications. When deploying the 4-20 mA current outputs, confirm the loop impedance remains within the designated limits of the 24 VDC driving loop.

5466-353 Woodward Analog Transceiver Board | New & Original Stock

Item no : 42706742267
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 7 - Aug 12

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches