HOS-100Q1 DC Current TransducerProduct Datasheet The HOS 100Q1 is a simple open loop DC transducer capable of measuring DC currents in the range of 100A. It is designed for applications where accurate current measurement is critical, such as power monitoring and energy management systems. The VT406 DC current transceiver bridges the measured data from the HOS 100Q1 transducer to the Vutlan monitoring system. This setup allows for real time monitoring and analysis of current flow,
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Datasheet

The HOS-100Q1 is a simple open-loop DC transducer capable of measuring DC currents in the range of ±100A. It is designed for applications where accurate current measurement is critical, such as power monitoring and energy management systems.

The VT406 DC current transceiver bridges the measured data from the HOS-100Q1 transducer to the Vutlan monitoring system. This setup allows for real-time monitoring and analysis of current flow, ensuring that any irregularities in the system are detected early, which is crucial for the protection and stability of electrical systems.

The combination of these two components offers a reliable solution for integrating current measurements into Vutlan's comprehensive monitoring infrastructure.

Use Cases

These use cases highlight the versatility of the HOS-100Q1 DC current transducer and the VT406 transceiver in monitoring, ensuring safe operations, and optimizing performance in various industries.

  • Solar Power Monitoring: Used to track the current flowing between solar panels and batteries or inverters in photovoltaic systems. The HOS-100Q1 monitors the DC current from solar arrays, and the VT406 transfers the data to the monitoring system for performance analysis and fault detection.
  • Wind Power Systems: In wind turbines, the DC current generated is monitored to ensure proper charging of storage systems or grid feedback, helping to maintain optimal system performance.
  • Monitoring the DC current flow between the grid and electric vehicles during the charging process to ensure safe and efficient charging. Abnormalities can be detected, preventing overcharging or electrical faults in the charging system.
  • Battery Discharge Monitoring: Measure the DC current to detect how much current is being drawn from batteries in backup power systems, such as uninterruptible power supplies (UPS), or electric vehicle batteries.
  • Battery Charging Control: Ensuring that charging currents are within safe limits, optimizing the lifespan of the batteries and ensuring their reliability.
  • Power Monitoring: The combination of HOS-100Q1 and VT406 helps monitor the power consumption of critical infrastructure in data centers, particularly in high-density server environments. It ensures that power draw from servers, cooling systems, and other equipment stays within optimal limits.
  • Power Backup Systems: In telecom facilities, where uninterrupted power is crucial, HOS-100Q1 can monitor the current flow from backup batteries to ensure proper performance during power outages, with VT406 transferring that data for remote monitoring.
  • Motor Current Monitoring: In automation and robotics, monitoring the DC current supplied to motors can help in predictive maintenance. The HOS-100Q1 ensures that motors operate within safe current ranges, while the VT406 helps integrate this data into a larger control system.
  • Process Control Systems: The transducer can be used in manufacturing plants to monitor currents in machinery, ensuring they are operating efficiently without overloading.
  • Monitoring the power supply for heating, ventilation, and air conditioning systems in large commercial or industrial buildings. This ensures that the current load remains stable and identifies potential issues before equipment fails.

Specifications

  • Device type: Current transducer
  • Measured current: ±100A, DC
  • Max. isolation voltage: 2kV
  • Max. cable diameter: 10 mm
  • Outputs: 4 pin terminal, pitch 3.81mm
  • Max. distance 50 m
  • Operating temperature: Min. -10° C - Max.80° C
  • Operating humidity: Min. 5% - Max. 95% (Non-Condensing)
  • Power input: ±12V “ ±15V
  • Dimensions: 60 — 61 — 16 mm

HOS-100Q1 DC Current Transducer

Item no : 77790173560
sold recently : Login >>
US$ 43.57
Pay in 4 interest-free payments of $10.89 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 23 - Jul 28

Enjoy 20% off shipping

US$ 43.57

1-11

US$ 39.21

12-35

US$ 30.50

36-59

US$ 26.14

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches