Wilkins 34-975XL3 | Reduced Pressure Principle Backflow PreventerNOTICE: Product images may vary from the actual item due to differences in size or configuration options. The Wilkins 34 975XL3 is a compact lead free reduced pressure principle backflow preventer designed for potable water protection against backsiphonage and backpressure contamination in health hazard applications. Key Specifications: Size: 3 4 Inches Maximum Working Water Pressure: 175 PSI Maximum Working Water Temperature: 180F Notable
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

NOTICE: Product images may vary from the actual item due to differences in size or configuration options.

The Wilkins 34-975XL3 is a compact lead-free reduced pressure principle backflow preventer designed for potable water protection against backsiphonage and backpressure contamination in health hazard applications.

 

Key Specifications:

  • Size: 3/4 Inches
  • Maximum Working Water Pressure: 175 PSI
  • Maximum Working Water Temperature: 180°F
  • Notable Certifications: ASSE 1013, cUPC, CSA B64.4
  • End Connections: FNPT Threaded ANSI B1.20.1

 

Other Related Variants:

  • 112-975XL3: 1 1/2 Inches model size
  • 114-975XL3: 1 1/4 Inches model size
  • 12-975XL3: 1/2 Inches model size
  • 1-975XL3: 1 Inches model size
  • 2-975XL3: 2 Inches model size

 

Materials:

  • Low Lead Cast Bronze (ASTM B 584) - Main valve body and access covers
  • Stainless Steel (300 Series) - Fasteners and springs
  • Silicone (FDA Approved) - Elastomers
  • Buna Nitrile (FDA Approved) - Elastomers
  • Noryl™ - Polymers and internal components
  • Stainless Steel - Ball valve handles

 

Typical Installation:

Designed for installation on potable water lines where lead-free valves are required to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches (305mm) and a maximum of 30 inches (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. If installed indoors, the installation shall be supplied with an air gap adapter.

 

Standards Compliance:

ASSE Listed 1013; cUPC Listed; CSA Certified B64.4; UL Classified (less shut-off valves); C-UL Classified; AWWA Compliant C511; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; NSF/ANSI/CAN 61 and 372 (Less than 0.25% Weighted Average Lead Content)

 

Features & Benefits:

  • Lead-Free Compliance: Meets NSF/ANSI/CAN 372 with less than 0.25% weighted average lead content for safe potable water applications.
  • Dual Protection: Protects against both backsiphonage and backpressure contamination where potential health hazards exist.
  • Easy Maintenance Access: First and second checks are accessible for maintenance without removing the relief valve or the entire device from the line, sharing a single access cover.
  • Durable Construction: Low lead cast bronze body with Noryl™ internal components, stainless steel springs, and FDA-approved silicone elastomers ensure long-lasting performance in demanding conditions.

 

FAQ

 

Q: What is the minimum working water pressure required for the Zurn 34-975XL3?

A: The minimum working water pressure required is 25 PSI to ensure proper operation of the reduced pressure principle assembly.

Q: What installation height is required for the Zurn 34-975XL3?

A: Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches (305mm) and a maximum of 30 inches (762mm) above adequate drains with sufficient side clearance for testing and maintenance.

Q: Can the checks be serviced without removing the entire device?

A: Yes, the first and second checks are accessible for maintenance without removing the relief valve or the entire device from the line. The checks share a single access cover and test cocks are accessible from the top of the device.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

Wilkins 34-975XL3 | Reduced Pressure Principle Backflow Preventer

Item no : 84790288005
sold recently : Login >>
US$ 465.00
Pay in 4 interest-free payments of $116.25 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 21 - Jul 26

Enjoy 20% off shipping

US$ 465.00

1-11

US$ 418.50

12-35

US$ 325.50

36-59

US$ 279.00

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches