MC-TAOX12 Honeywell Experion PKS Datasheet & Technical ManualHoneywell MC TAOX12 Experion PKS Analog Output Module The Honeywell MC TAOX12, also cataloged as the Honeywell 51304441 175 Analog Output Field Termination Assembly, operates as a dedicated hardware component for converting digital control commands into analog current loops within Experion PKS, HPM, and TDC 3000 control architectures. Hardware Specifications Parameter Specification Model MC TAOX12 Part Number 51304441 175 Brand Honeywell Channel Count
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Honeywell MC-TAOX12 Experion PKS Analog Output Module

The Honeywell MC-TAOX12, also cataloged as the Honeywell 51304441-175 Analog Output Field Termination Assembly, operates as a dedicated hardware component for converting digital control commands into analog current loops within Experion PKS, HPM, and TDC 3000 control architectures.

Hardware Specifications

Parameter Specification
Model MC-TAOX12
Part Number 51304441-175
Brand Honeywell
Channel Count 16 independent channels
Signal Range 4-20 mA DC
Nominal Supply Voltage 24 VDC
Power Consumption 6 W maximum
Environmental Protection Full conformal coating
Isolation Galvanic isolation (system-to-field)
Wiring Terminal Type Compression-style screw terminals
Operating Temp 0 to 60 deg C
Dimensions Standard 6-inch FTA profile
Weight 0.45 kg
Origin USA

DCS Process Control and Loop Protocols

The Honeywell MC-TAOX12 employs a dedicated 4-20 mA HART loop protocol layer, which ensures linear signal transmission to final control elements like actuators, control valves, and current-to-pressure (I/P) transducers. Channel-to-channel isolation parameters prevent ground loop currents from destabilizing adjacent analog outputs, maintaining electrical decoupling between the field connections and the system backplane. Additionally, the integrated electronic assembly features automated cold junction compensation and fault-detection metrics that track circuit loop integrity, driving outputs to a predefined safe state during a processor-to-FTA communication timeout.

Frequently Asked Questions

Q: What is the physical functional difference between the MC-TAOX12 and the MU-TAOX12 assemblies?

A: The MC-TAOX12 features factory-applied conformal coating on the printed circuit board assembly to resist environmental contaminants, whereas the MU-TAOX12 lacks this additional layer. Both modules share identical electrical characteristics and loop logic.

Q: How does the MC-TAOX12 handle I/O processor redundancy?

A: The hardware architecture provides dual physical cable connection points on the assembly layout. This enables two redundant I/O processors to establish parallel communication links with a single FTA, ensuring bumpless transfer during processor switchovers.

Q: Can this module operate using a 0-20 mA output configuration?

A: No, the hardware profile and internal firmware configuration restrict the operational signal range exclusively to standard 4-20 mA DC analog current loops.

Field Installation Guidelines

  • Mounting Orientation and Clearance: Mount the FTA on standard high-density terminal tracks inside the enclosure. Maintain a minimum clearance of 50 mm above and below the board assembly to facilitate natural thermal dissipation.
  • Wiring Practices: Strip field wires back by 7 mm before insertion into the compression-style screw terminals. Tighten all screw terminal blocks to a torque specification between 0.5 Nm and 0.6 Nm to ensure gas-tight contacts.
  • Shielding and Grounding: Terminate the shield drain wires of all field cables at the designated cabinet instrument ground bar. Do not ground the cable shield at both the FTA end and the field instrument end simultaneously to eliminate potential ground loops.
  • Conduit Entry: Run analog output field lines through distinct, dedicated cable trays or conduits separate from high-voltage AC power distribution wiring to minimize electromagnetic interference.

MC-TAOX12 Honeywell Experion PKS Datasheet & Technical Manual

Item no : 91906764570
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 7 - Aug 12

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches