20% OFF shipping at www.midwoodautocraft.com on orders over $79 + up to 10% OFF products
www.midwoodautocraft.com
home > Buy New Woodward 8271-468 D Load Regulation Module > Buy New Woodward 8271-468 D Load Regulation Module
download picture
Buy New Woodward 8271-468 D Load Regulation ModuleProduct Overview The Woodward 8271 468 D acts as a critical command interface for complex power generation environments. This module monitors real time generator loads and generates a calibrated bias voltage signal to regulate output. It enables multiple engine generator sets to share loads proportionally, preventing "load hogging" or reverse power conditions. Whether operating against an infinite bus or in an isolated microgrid, the 8271 468 D
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Overview

The Woodward 8271-468 D acts as a critical command interface for complex power generation environments. This module monitors real-time generator loads and generates a calibrated bias voltage signal to regulate output. It enables multiple engine-generator sets to share loads proportionally, preventing "load-hogging" or reverse power conditions. Whether operating against an infinite bus or in an isolated microgrid, the 8271-468 D maintains frequency stability and ensures balanced power distribution across the entire system.

Technical Specifications

The Woodward 8271-468 D provides dual-voltage compatibility and specialized analog outputs for seamless governor interfacing.

Parameter Specification
Catalog Number 8271-468 D
Control Functions Isochronous and Droop Load Regulation
Input Power 115 VAC or 230 VAC (Selectable)
Output Signal Calibrated Bias Voltage Signal
Load Sharing Ratio 1:15
Compatible Controllers Woodward 2301, 2301A, EG, EPG, 2500 Series
Mounting Configuration Rugged Panel Mount
Weight 4lbs (1.8 kg)
Dimensions 250 mm × 120 mm × 40 mm
Operating Temp Range 0°C to +60°C

Engineering Advantages

  • Dual Control Modality: The module supports both isochronous (constant frequency) and droop (proportional speed drop) modes. This flexibility allows engineers to configure the unit for standalone mission-critical backup or for parallel operation with a utility grid.

  • Inter-System Synergy: This unit specifically complements legacy and modern Woodward speed controllers like the 2301A and EPG series. It bridges the gap between raw speed sensing and intelligent load management without requiring complex PLC programming.

  • Industrial Hardening: The 8271-468 D features a robust metal chassis designed for high-vibration environments such as marine engine rooms and containerized power modules. The panel-mount design facilitates rapid installation into standard NEMA enclosures.

  • Precision Load Balancing: The 1:15 load sharing ratio allows for precise fine-tuning of the system. It ensures that generators of different capacities distribute the electrical burden based on their rated percentages, maximizing fuel efficiency and extending engine life.

FAQs

Q: Can the 8271-468 D be used with non-Woodward governors?

A: This module generates a standard bias voltage signal. While optimized for Woodward controllers (2301/2500 series), it can interface with any electronic governor that accepts an analog bias input for speed/load offset, provided the voltage levels align.

Q: How do I switch between 115 VAC and 230 VAC input power?

A: The module features specific terminal jumper configurations to select the input voltage. Refer to the wiring schematic on the side of the chassis before applying power to prevent internal transformer damage.

Q: What is the difference between the "D" suffix and older versions?

A: The "D" revision signifies updated internal components and improved thermal dissipation over earlier iterations of the 8271-468. It maintains the same footprint and terminal logic, making it a direct drop-in replacement for older 8271-468 models.

Q: Does this unit require a separate load sensor?

A: The 8271-468 D typically requires Current Transformers (CTs) and Potential Transformers (PTs) to sense the generator's actual power output. It processes these raw AC signals to calculate the real load (kW) before issuing a correction signal to the governor.

Buy New Woodward 8271-468 D Load Regulation Module

Item no : 98035170400
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 8 - Aug 13

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches