Shopping security
The Bently Nevada 106M1079-01, also cataloged as the 3500/15 Universal AC Power Supply Module, operates as a dedicated hardware component for primary voltage conversion and stabilization within Bently Nevada 3500 Machinery Protection System platforms. This half-height module receives raw power from a paired rear-mounted Power Input Module, transforming the incoming wide-range AC mains into regulated secondary DC lines required to energize backplane logic buses, transducer drivers, and instrumentation modules. It installs exclusively into the dedicated left-side columns of the 3500/05 system chassis.
| Parameter | Specification |
|---|---|
| Model | 3500/15 |
| Brand | Bently Nevada |
| Origin | USA |
| Part Number | 106M1079-01 |
| Product Type | Universal AC Power Supply Module |
| Input Voltage Range | 85 to 264 V AC RMS |
| Input Frequency | 47 to 63 Hz |
| Efficiency | 85% typical at maximum load |
| Output Voltages | Internally regulated DC rails for 3500 backplane |
| Redundancy Support | Load-sharing / Automatic failover |
| Hot-Swap Support | Permitted when redundant supply is active |
| Operating Temp | -30 to +65 deg C |
| Storage Temp | -40 to +85 deg C |
| Relative Humidity | 95% non-condensing |
| Dimensions | 120.7 mm x 50.8 mm x 251.5 mm |
| Weight | 1.39 kg |
| Power Consumption | Determined by total instrumentation load |
The internal step-down circuitry inside this module maintains precise secondary voltage tolerances to prevent localized electrical interference from corrupting critical sensor paths. During the real-time processing of high-frequency waveforms for rotor dynamics tracking, the module actively regulates target output rails to ensure steady gap voltage validation (-10 VDC targets) across all proximity probe channels. This isolated regulation prevents line-side harmonics from causing signal noise on adjacent slots. Furthermore, the integrated load-sharing bus layout incorporates active cross-talk suppression, which ensures that electrical switching transients during a redundant supply transition do not cause false trips or disrupt eddy-current probe scaling configurations.
Q: Under what specific conditions can the 106M1079-01 module be hot-swapped?
A: Hot-swapping is permitted only when a second 3500/15 power supply is fully functional and sharing the chassis load in a redundant configuration. If the rack operates on a single power supply, removing the card will drop the backplane DC rails and shut down the system.
Q: How does the load-sharing mechanism operate during normal conditions?
A: When two modules are installed in a redundant pair, the internal diode-ORing logic automatically balances the current draw, allowing both units to divide the thermal and electrical load equally to extend component longevity.
Q: Does the 106M1079-01 require physical jumper modifications to handle different international AC mains?
A: No. The universal internal regulator circuit adapts automatically to any input voltage spanning from 85 to 264 V AC RMS without requiring manual internal configuration switches or specific field wiring adjustments.
Ships within 48 hours · Estimated delivery Aug 6 - Aug 11
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order