Shopping security
The COMEN NC7 Patient Monitor is a cutting-edge device designed for use in a wide range of clinical settings. It is ideal for ward rounds, triage, and bedside monitoring and is suitable for both routine checks and critical care situations. Utilising advanced technology, the NC7 accurately monitors a wide range of parameters, streamlining workflows and enhancing patient safety.
The NC7 features a user-friendly interface that enables intuitive operation, making it easy to create tasks and customised workflows. The monitor supports both spot checks and continuous monitoring, with personalised settings for parameters and views that simplify daily tasks and enhance patient care.
The NC7 provides seamless data connectivity, effortlessly integrating with CMS systems via its integrated HL7 interface for quick and straightforward data transfer. The monitor includes early warning scoring systems such as MEWS, NEWS, NEWS2, and PEWS as well as the Glasgow Coma Scale (GCS) for assessing the consciousness level of comatose patients. It also supports pain level assessment via pain score.
For maximum flexibility, the NC7 is compatible with thermometers from various manufacturers. An optional trolley with a backup battery system allows for uninterrupted monitoring even in critical situations.
Please note that no EtCo2 module is included. The thermometer shown in the image is from a different manufacturer. Instead, you will receive the YHT 107 ear thermometer with your patient monitor.
| Physical Properties | |
| Dimensions | 270 x 150 x 265 mm |
| Weight | Approx. 4.2 kg |
| Touchscreen | 1280 x 800 px, 10.1 inches |
| NIBP | |
| Standard | IEC 80601-2-30 |
| Method | Oscillometric, Inflation and Deflation |
| Operating Modes | Manual, Interval, Spot, Sequences, STAT, Orthostatic Blood Pressure, NIBP Averaging |
| Parameters | Systole, Diastole, Mean, Heart Rate |
| Typical Measurement Time | Approx. 15 seconds |
| Maximum Measurement Time | Adults/Children approx. 120 seconds, Newborns approx. 85 seconds |
| Measurement Interval | 1-720 minutes (adjustable) |
| Measurement Units | mmHg/kPa (selectable) |
| Measurement Range | 0-300 mmHg (0-40.0 kPa) |
| Measurement Accuracy | ±3 mmHg (±0.4 kPa) |
| NIBP Resolution | 1 mmHg |
| Venepuncture | Yes |
| SpO2 | |
| Standard | ISO 80601-2-61 |
| Measurement Range | Comen, Masimo, Nellcor, Mindray/Nellcor: 0 to 100% Masimo: 1-100% |
| Resolution | 1% |
| Accuracy | Adults/Children: ±2% (70-100%); Newborns: ±3% (70-100%) |
| Alarm Range | 1-100% |
| Perfusion Index | Yes, for Comen and Masimo |
| Audible Alarm | Yes, adjustable volume |
| Response Time | <30 seconds |
| Dual SpO2 | Yes, SpO2, SpO2b, ΔSpO2 (brand should be uniform) |
| Heart Rate | |
| Measurement Range | 30-300 bpm (Comen NIBP) 20-300 bpm (Comen SpO2) 25-240 bpm (Masimo SpO2) 20-300 bpm (Nellcor SpO2) |
| Respiratory Rate | |
| Measurement Range | 4-70 rpm |
| Accuracy | ±3 rpm |
| Resolution | 1 rpm |
| Measurement Duration | ≤ 30s |
| Update Duration | 1 second |
| EtCO2 (not included) | |
| Standard | ISO 80601-2-55 |
| Technique | Infrared Absorption |
| Measurement Units | mmHg, kPa |
| Sampling Rate | 50 ml/min |
| Resolution | 1 mmHg |
| Temperature | |
| Measurement Type | Ear |
| Temperature Range | 34-42.2 °C |
| Power Supply | DC 3V, 2 x 1.5 V AA Alkaline Batteries |
Ships within 48 hours · Estimated delivery Jun 27 - Jul 2
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off